16kVA on-line double-conversion UPS with 12U rack/tower. Ideal for critical server, network and telecommunications equipment in a 12U rack/tower configuration. System delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions.
Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under
Included parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal
Supports 50/60Hz operation
Expandable runtime with optional external battery packs
Battery independent restart
Highly efficient economy mode option
Optional SNMPWEBCARD, RELAYIOCARD and RELAYIOMINI interface modules available (RELAYIOMINI requires removal of USB interface module)
HID-compliant USB interface
Includes free PowerAlert monitoring software, PowerAlert LOCAL, PowerAlert NSA and PowerAlert
NMS for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices
Supports emergency power off (EPO) via built-in interface
Front panel LEDs and LCD readout with scroll controls
LED/LCD display panel rotates for viewing in rackmount or tower configurations
External battery packs are field replaceable and hot swappable
Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Warranty - Yes
Rackmountable - Yes
UL Rated - Yes
Spec Sheet available - Yes
Operating Temperature (Maximum):
104 F
Operating Temperature (Minimum):
32 F
Estimated Runtime:
5.50 minutes
Output volt amp capacity:
16000 VA
Output Watt Capacity:
14400 W
Nominal Output Voltage (Supported):
200/208/220/230/240 V
Frequency Compatibility:
50/60 Hz
Built-in UPS output receptacles:
8 x L6 to 20R and 2 x L6 to 30R outlets
Rated input current (at maximum load):
92A (200V), 88.4A (208V), 83.6A (220V), 80A (230V) and 76.6A (240V)
Nominal Input Voltage (Supported):
208/240 VAC
Input Connection Type:
Hardwire
Battery Full Load Runtime:
5.5 minutes (14,400W)
Battery Half Load Runtime:
13.5 minutes (7200W)
DC Battery System Voltage:
240 VDC
Primary Form Factor:
Rackmount
Shipping Dimensions:
5.25 x 17.5 x 25 inches
UPS housing material:
Steel
Cooling Method:
Fan
Package Includes:
Two SU8000RT3UPM UPS power modules, two BP240V10RT3U battery packs, parallel PDU with bypass switch, 4-post rackmount installation rails and PowerAlert software and cable